1.
Comput Math Methods Med ; 2020: 1793517, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32952597

RESUMO

An artificial stent implantation is one of the most effective ways to treat coronary artery diseases. It is vital in vascular medical imaging, such as intravascular optical coherence tomography (IVOCT), to be able to track the position of stents in blood vessels effectively. We trained two models, the "You Only Look Once" version 3 (YOLOv3) and the Region-based Fully Convolutional Network (R-FCN), to detect metal support struts in IVOCT, respectively. After rotating the original images in the training set for data augmentation, and modifying the scale of the conventional anchor box in both two algorithms to fit the size of the target strut, YOLOv3 and R-FCN achieved precision, recall, and AP all above 95% in 0.4 IoU threshold. And R-FCN performs better than YOLOv3 in all relevant indicators.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Stents , Tomografia de Coerência Óptica/métodos , Algoritmos , Biologia Computacional , Aprendizado Profundo , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Interpretação de Imagem Assistida por Computador/estatística & dados numéricos , Conceitos Matemáticos , Metais , Desenho de Prótese , Tomografia de Coerência Óptica/estatística & dados numéricos
2.
Comput Math Methods Med ; 2020: 1405647, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32411276

RESUMO

Magnetic resonance (MR) images are often contaminated by Gaussian noise, an electronic noise caused by the random thermal motion of electronic components, which reduces the quality and reliability of the images. This paper puts forward a hybrid denoising algorithm for MR images based on two sparsely represented morphological components and one residual part. To begin with, decompose a noisy MR image into the cartoon, texture, and residual parts by MCA, and then each part is denoised by using Wiener filter, wavelet hard threshold, and wavelet soft threshold, respectively. Finally, stack up all the denoised subimages to obtain the denoised MR image. The experimental results show that the proposed method has significantly better performance in terms of mean square error and peak signal-to-noise ratio than each method alone.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Encéfalo/diagnóstico por imagem , Biologia Computacional , Simulação por Computador , Bases de Dados Factuais , Humanos , Interpretação de Imagem Assistida por Computador/estatística & dados numéricos , Neuroimagem/estatística & dados numéricos , Distribuição Normal , Análise de Componente Principal , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído , Análise de Ondaletas
3.
Comput Math Methods Med ; 2020: 7902072, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32454884

RESUMO

Electroencephalography (EEG) plays an import role in monitoring the brain activities of patients with epilepsy and has been extensively used to diagnose epilepsy. Clinically reading tens or even hundreds of hours of EEG recordings is very time consuming. Therefore, automatic detection of seizure is of great importance. But the huge diversity of EEG signals belonging to different patients makes the task of seizure detection much challenging, for both human experts and automation methods. We propose three deep transfer convolutional neural networks (CNN) for automatic cross-subject seizure detection, based on VGG16, VGG19, and ResNet50, respectively. The original dataset is the CHB-MIT scalp EEG dataset. We use short time Fourier transform to generate time-frequency spectrum images as the input dataset, while positive samples are augmented due to the infrequent nature of seizure. The model parameters pretrained on ImageNet are transferred to our models. And the fine-tuned top layers, with an output layer of two neurons for binary classification (seizure or nonseizure), are trained from scratch. Then, the input dataset are randomly shuffled and divided into three partitions for training, validating, and testing the deep transfer CNNs, respectively. The average accuracies achieved by the deep transfer CNNs based on VGG16, VGG19, and ResNet50 are 97.75%, 98.26%, and 96.17% correspondingly. On those results of experiments, our method could prove to be an effective method for cross-subject seizure detection.


Assuntos
Aprendizado Profundo , Diagnóstico por Computador/estatística & dados numéricos , Eletroencefalografia/estatística & dados numéricos , Convulsões/diagnóstico , Criança , Biologia Computacional , Bases de Dados Factuais/estatística & dados numéricos , Epilepsia/diagnóstico , Análise de Fourier , Humanos , Redes Neurais de Computação , Processamento de Sinais Assistido por Computador
4.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 32(6): 1179-84, 2015 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-27079083

RESUMO

Electrocardiogram (ECG) signals are susceptible to be disturbed by 50 Hz power line interference (PLI) in the process of acquisition and conversion. This paper, therefore, proposes a novel PLI removal algorithm based on morphological component analysis (MCA) and ensemble empirical mode decomposition (EEMD). Firstly, according to the morphological differences in ECG waveform characteristics, the noisy ECG signal was decomposed into the mutated component, the smooth component and the residual component by MCA. Secondly, intrinsic mode functions (IMF) of PLI was filtered. The noise suppression rate (NSR) and the signal distortion ratio (SDR) were used to evaluate the effect of de-noising algorithm. Finally, the ECG signals were re-constructed. Based on the experimental comparison, it was concluded that the proposed algorithm had better filtering functions than the improved Levkov algorithm, because it could not only effectively filter the PLI, but also have smaller SDR value.


Assuntos
Algoritmos , Eletrocardiografia , Humanos